Name:
[FIX] survey: keep the action helper alive when the RPC is unreachable
State:
Failed
finished in 174m
PR State:
open
PR Author:
Roy Le
PR Author Email:
PR:
#1315
Committer:
Roy Le
Committer Email:
roy.le@viindoo.com
Commit:
3d383b49f85e433275502fd2aed8c5e9a48a1f05
Description:
[FIX] survey: keep the action helper alive when the RPC is unreachable
`SurveySurveyActionHelper` (shown when the survey list/kanban is empty)
fetches the sample templates in `onWillStart` and lets any error
through.
In the offline clickbot (`TestMenusAdminLight.test_02_click_apps_menus_
as_admin_offline`) that RPC is cut and the whole Surveys app fails:
Error found:
- Current testing app is Surveys (survey.menu_surveys)
- Currently running offline
Connection to
"/web/dataset/call_kw/survey.survey/get_survey_templates_data"
couldn't be established or was interrupted
Odoo's runbot never renders the helper during that test because the
enterprise `hr_appraisal_survey` ships surveys as regular data; a
community-only database without demo data has an empty list and hits it.
Swallow `ConnectionLostError` only and render the helper without
templates: "Start from scratch" stays available, other errors still
propagate.
Verified with `-i survey,web --test-enable
--test-tags=/web:TestMenusAdminLight`
on a community checkout without demo data: test_02 fails without this
change and passes with it (2/2).